pre cleaned resin Search Results


90
Eichrom Technologies LLC cation exchange resin eichrom ag50wx8 200–400 mesh
Ion exchange chromatography procedure for Ru isolation and purification.
Cation Exchange Resin Eichrom Ag50wx8 200–400 Mesh, supplied by Eichrom Technologies LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/cation exchange resin eichrom ag50wx8 200–400 mesh/product/Eichrom Technologies LLC
Average 90 stars, based on 1 article reviews
cation exchange resin eichrom ag50wx8 200–400 mesh - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

95
Bio-Rad pre cleaned bio rad cation resin ag50w x12
Ion exchange chromatography procedure for Ru isolation and purification.
Pre Cleaned Bio Rad Cation Resin Ag50w X12, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 95/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pre cleaned bio rad cation resin ag50w x12/product/Bio-Rad
Average 95 stars, based on 1 article reviews
pre cleaned bio rad cation resin ag50w x12 - by Bioz Stars, 2026-05
95/100 stars
  Buy from Supplier

96
Bio-Rad pre cleaned biorad ag50 w x8
Ion exchange chromatography procedure for Ru isolation and purification.
Pre Cleaned Biorad Ag50 W X8, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pre cleaned biorad ag50 w x8/product/Bio-Rad
Average 96 stars, based on 1 article reviews
pre cleaned biorad ag50 w x8 - by Bioz Stars, 2026-05
96/100 stars
  Buy from Supplier

93
Bio-Rad pre cleaned bio rad ag mp 50
Ion exchange chromatography procedure for Ru isolation and purification.
Pre Cleaned Bio Rad Ag Mp 50, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pre cleaned bio rad ag mp 50/product/Bio-Rad
Average 93 stars, based on 1 article reviews
pre cleaned bio rad ag mp 50 - by Bioz Stars, 2026-05
93/100 stars
  Buy from Supplier

93
Bio-Rad pre cleaned ag1x8
Ion exchange chromatography procedure for Ru isolation and purification.
Pre Cleaned Ag1x8, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 93/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pre cleaned ag1x8/product/Bio-Rad
Average 93 stars, based on 1 article reviews
pre cleaned ag1x8 - by Bioz Stars, 2026-05
93/100 stars
  Buy from Supplier

90
Eichrom Technologies LLC dga resin
Ion exchange chromatography procedure for Ru isolation and purification.
Dga Resin, supplied by Eichrom Technologies LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/dga resin/product/Eichrom Technologies LLC
Average 90 stars, based on 1 article reviews
dga resin - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Eichrom Technologies LLC eichrom sr-spec resin
Ion exchange chromatography procedure for Ru isolation and purification.
Eichrom Sr Spec Resin, supplied by Eichrom Technologies LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/eichrom sr-spec resin/product/Eichrom Technologies LLC
Average 90 stars, based on 1 article reviews
eichrom sr-spec resin - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Eichrom Technologies LLC sr-specific resin
Ion exchange chromatography procedure for Ru isolation and purification.
Sr Specific Resin, supplied by Eichrom Technologies LLC, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/sr-specific resin/product/Eichrom Technologies LLC
Average 90 stars, based on 1 article reviews
sr-specific resin - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

90
Beijing CWBio protein a resin
Ion exchange chromatography procedure for Ru isolation and purification.
Protein A Resin, supplied by Beijing CWBio, used in various techniques. Bioz Stars score: 90/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/protein a resin/product/Beijing CWBio
Average 90 stars, based on 1 article reviews
protein a resin - by Bioz Stars, 2026-05
90/100 stars
  Buy from Supplier

94
Bio-Rad pre cleaned anion exchange resin
Ion exchange chromatography procedure for Ru isolation and purification.
Pre Cleaned Anion Exchange Resin, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 94/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/pre cleaned anion exchange resin/product/Bio-Rad
Average 94 stars, based on 1 article reviews
pre cleaned anion exchange resin - by Bioz Stars, 2026-05
94/100 stars
  Buy from Supplier

96
Bio-Rad poly prep columns
Ion exchange chromatography procedure for Ru isolation and purification.
Poly Prep Columns, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/poly prep columns/product/Bio-Rad
Average 96 stars, based on 1 article reviews
poly prep columns - by Bioz Stars, 2026-05
96/100 stars
  Buy from Supplier

96
Bio-Rad ag 1x8 200 400 mesh pre cleaned resin
Ion exchange chromatography procedure for Ru isolation and purification.
Ag 1x8 200 400 Mesh Pre Cleaned Resin, supplied by Bio-Rad, used in various techniques. Bioz Stars score: 96/100, based on 1 PubMed citations. ZERO BIAS - scores, article reviews, protocol conditions and more
https://www.bioz.com/result/ag 1x8 200 400 mesh pre cleaned resin/product/Bio-Rad
Average 96 stars, based on 1 article reviews
ag 1x8 200 400 mesh pre cleaned resin - by Bioz Stars, 2026-05
96/100 stars
  Buy from Supplier

Image Search Results


Ion exchange chromatography procedure for Ru isolation and purification.

Journal: International journal of mass spectrometry

Article Title: Refinement of high precision Ru isotope analysis using negative thermal ionization mass spectrometry

doi: 10.1016/j.ijms.2016.02.003

Figure Lengend Snippet: Ion exchange chromatography procedure for Ru isolation and purification.

Article Snippet: In detail, the 1° column cation exchange chromatography used ~10 ml of pre-cleaned Eichrom AG50WX8 200–400 mesh cation exchange resin equilibrated in Milli-Q water (see for pre-cleaning steps and for elution protocol).

Techniques: Ion Exchange Chromatography, Isolation, Purification

Ion exchange chromatography procedure for Ru isolation and purification.

Journal: International journal of mass spectrometry

Article Title: Refinement of high precision Ru isotope analysis using negative thermal ionization mass spectrometry

doi: 10.1016/j.ijms.2016.02.003

Figure Lengend Snippet: Ion exchange chromatography procedure for Ru isolation and purification.

Article Snippet: Subsequently, for those samples requiring column chromatography, better Ru yields were achieved by proceeding directly from the 1° column chemistry to a microdistillation. table ft1 table-wrap mode="anchored" t5 caption a7 Acid Volume (ml) Step 1° cation column: 2–4 Biorad columns filled with 10 ml of pre-cleaned AG50WX8 (200–400 mesh) Milli-Q water 20 Resin cleaning 6M HCl 10 + 10 + 10 + 10 Resin cleaning Milli-Q water 20 Resin cleaning 0.15 M HCl 10 Backwash 0.15 M HCl 10 Equilibration 0.15 M HCl 2.5 Load 0.15 M HCl 1 + 1 +1 + 5 Rinse HSE 6 M HCl 1 + 1 + 1 + 27 Rinse matrix 6 M HCl 10 + 10 + 10 + 10 + 10 + 10 Resin cleaning Milli-Q water 20 Resin cleaning 2° anion column: 1 Biorad column filled with 3.8 ml of pre-cleaned AG1X8 (200–400 mesh) Milli-Q water 10 Resin cleaning Concentrated HNO3 10 + 10 Resin cleaning Milli-Q water 5 Resin cleaning Concentrated HCl 10 Resin cleaning Milli-Q water 5 Resin cleaning 1 M HCl 3 Backwash 1 M HCl 4 Equilibration 1 M HCl 1 Load 0.5 M HCl 2 Matrix, Mo 0.8 M HNO3 0.5 Matrix, Mo 0.8 M HNO3 5 Zn, Cd, Mo 8 M HNO3 10 Ru, Re Concentrated HNO3 4 Ru, Re Concentrated HNO3 10 Pt, Ir 11 M HCl 2 Pt, Ir, Ag 11 M HCl 8 Pd Concentrated HNO3 5 Pd Open in a separate window Ion exchange chromatography procedure for Ru isolation and purification.

Techniques: Ion Exchange Chromatography, Isolation, Purification